Solving 10 Common Central Heating Pump Problems
Central heating pumps play a crucial role in keeping your heating system running smoothly. When issues arise, understanding the problem and its solution can save you time and money. In this article, we'll address nine common central heating pump problems concisely.
1. No Water Circulation Issue:
The pump is running, but no water circulates. Cause: Likely a stuck shaft or propeller. Solution: Gently tap the pump to free up any seized components. Consider replacing the pump if this problem persists.
2. Blockages Issue:
Reduced or no heating due to a blocked pump. Cause: Accumulated dirt and debris. Solution: Hot flush the system with chemicals, and install a magnetic system filter to prevent future blockages.
3. Airlocks and Noise Issue:
Noisy pump or reduced functionality due to airlocks. Cause: Air buildup in the pump. Solution: Locate the pump's bleed screw, release air slowly, and consider using anti-vibration brackets for noise reduction.
4. Incorrect Installation Issue:
Long-standing heating problems may result from improper pump installation. Cause: Rarely, the pump might have been installed incorrectly. Solution: Drain the system, reinstall the pump correctly, and bleed radiators and towel rails. It helps if its the right way up!
5. Pump Speed Settings Issue:
Radiators not getting hot due to incorrect pump speed. Cause: Low flow rate settings. Solution: Adjust the pump speed setting to a higher level, but consult a professional if unsure.
6. Leaking Pump Issue:
Boiler leaks often trace back to pump issues. Cause: Loose pump, corrosion, or blown seal. Solution: Tighten the pump, check for corrosion, and replace the seal or pump if necessary.
7. No Power Issue:
Pump and boiler lack power. Cause: Possible PCB issues or wiring problems. Solution: Check fuses, inspect for leaks, and have a professional examine the wiring. Consider pump replacement if it's old and corroded.
8. Pump Won't Turn Off Issue:
Pump runs continuously without switching off. Cause: Faulty PCB, pump overrun stat, or sticking mid-position valve. Solution: Diagnose and address the specific issue.
9. Worn-Out Pump Issue:
Pump malfunctions due to age and wear. Cause: Long-term wear and tear (typically after 15-30 years). Solution: Replace the worn-out pump with a new one.
10. Pump blowing fuses
This is a common one, the pump is blowing the 3 amp fuse in the spur or tripping your RCD! Often you figure this out by disconnecting the live & re-establishing the power. Cause a dead-short in the electrics, usually caused by water being where it shouldn't be! Solution: you guessed it! New pump!
In conclusion, understanding these common central heating pump problems and their solutions can help you maintain a warm and efficient home. If you encounter issues beyond your expertise, don't hesitate to seek professional assistance.